2. APPLIANCE DATA, EFFICIENCY AND NO
x
2.1 General information.
Under no circumstances is this fire to be converted to LPG. An LPG conversion kit
does not exist for this gas fire.
The appliance information label is located on the base of the fire underneath the
burner module.
2.2 Efficiency.
The efficiency of this appliance has been measured as specified in BS 7977 - 1 and
the result is as below:
Model Efficiency % (Gross)
961 80
The gross calorific value of the fuel has been used for this efficiency calculation. The
test data from which it has been calculated has been certified by Advantica
Certification services (0087). The efficiency value may be used in the UK
Government's Standard Assessment Procedure (SAP) for energy rating of dwellings.
The conversion of net efficiency to gross was achieved by multiplying the net
efficiency by the following conversion factor from Table E3 of SAP 2005, rounding
down to the nearest whole number.
INSTALLER GUIDE
Page 8
© GDC Group Ltd. 2012
Gas Natural (G20)
Inlet Pressure 20mbar
Input - Max. (Gross) 5.00kW (17,060 Btu/h)
Input - Min. (Gross) 2.5kW (8,530 Btu/h)
Inlet Test Pressure (Cold) 20.0 ± 1.0mbar (8.0 ± 0.4in w.g.)
Gas Connection 8mm pipe
Burner Injector Cat 82 - 065
Pilot & Atmosphere Sensing Device Copreci Ref. O.D.S 21500/166
Ignition Electronic (Battery 9V PP3)
Aeration Setting See section 16.1